Calibration & Testing Services

The items of test services and methods for testing laboratory
  • Conductor resistance test
  • A.C. voltage test
  • Insulation resistance test
Test methods for Conductor resistance
test sample test methods
Cross-linked polyethylene insulated polyvinyl chloride jacketed power cables CNS 2655 Sec.4.13,CNS 689 Sec.6, IEC60502-1 Sec.15.2,JIS C3605 Sec.6.3, JIS C3005 Sec.4.4
Polyvinyl chloride insulated wires CNS 679 Sec.5.3,CNS 689 Sec.6, JIS C3307 Sec.6.3,JIS C3005 Sec.4.4
Polyvinyl chloride insulated polyvinyl chloride sheathed cables CNS 3301 Sec.5.3,CNS 689 Sec.6, JIS C3342 Sec.6.3,JIS C3005 Sec.4.4
Polyethylene(Cross-linked Polyethylene) insulated and Polyvinyl chloride (polyethylene) sheathed fire-resistant cables CNS 11359 Sec.5.3,CNS 689 Sec.6
Fire-resistant wires CNS 10314 Sec.6.3,CNS 689 Sec.6
Low smoke free halogen wires & cables IEC60502-1 Sec.15.2
Test methods for A.C.voltage test
test sample test methods
Cross-linked polyethylene insulated polyvinyl chloride jacketed power cables CNS 2655 Sec.4.13,CNS 689 Sec.6,IEC60502-1 Sec.15.2,JIS C3605 Sec.6.3, JIS C3005 Sec.4.4
Polyvinyl chloride insulated wires CNS 679 Sec.5.3,CNS 689 Sec.6, JIS C3307 Sec.6.3,JIS C3005 Sec.4.4
Polyvinyl chloride insulated polyvinyl chloride sheathed cables CNS 3301 Sec.5.3,CNS 689 Sec.6, JIS C3342 Sec.6.3,JIS C3005 Sec.4.4
Polyethylene(Cross-linked polyethylene) insulated and polyvinyl chloride (polyethylene) sheathed fire-resistant cables CNS 11359 Sec.5.3,CNS 689 Sec.6
Fire-resistant wires CNS 10314 Sec.6.3,CNS 689 Sec.6
Low smoke free halogen wires & cables IEC60502-1 Sec.15.2
Test methods for Insulation resistance test
test sample test methods
Cross-linked polyethylene insulated polyvinyl chloride jacketed power cables CNS 2655 Sec.4.12,JIS C3605 Sec.6.5, JIS C3005 Sec.4.7.1
Polyvinyl chloride insulated wires CNS 679 Sec. 5.5.1 ,5.5.2,CNS 689 Sec.9.1 & 9.2, JIS C3307 Sec.6.5.1 & 6.5.2,JIS C3005 Sec.4.7.1 & 4.7.2
Polyvinyl chloride insulated polyvinyl chloride sheathed cables CNS 3301 Sec.5.5,CNS 689 Sec.9.1, JIS C3342 Sec.6.5,JIS C3005 Sec.4.7.1
Polyethylene(Cross-linked polyethylene) insulated and polyvinyl chloride(polyethylene) sheathed fire-resistant cables CNS 11359 Sec.5.5,CNS 689 Sec.9.1
Fire-resistant wires CNS 10314 Sec.6.5,CNS 689 Sec.9 1
Heat-resistant wires CNS 679 Sec.5.5.1 & 5.5.2,CNS 689 Sec.9.1 & 9.2
  • Tensile strength and elongation test
  • Aging test
Test methods for tensile strength and elongation test
test sample test methods
Cross-linked polyethylene insulated polyvinyl chloride jacketed power cables CNS 2655 Sec.4.2,CNS 689 Sec.16, JIS C3605 Sec.6.6,JIS C3005 Sec.4.16, IEC60502-1 Sec.18.3 & 18.4,IEC60811-1-1 Sec.9.1 & 9.2
Polyvinyl chloride insulated wires CNS 679 Sec.5.6,CNS 689 Sec.16, JIS C3307 Sec.6.6,JIS C3005 Sec.4.16
Polyvinyl chloride insulated polyvinyl chloride sheathed cables CNS 3301 Sec.5.6,CNS 689 Sec.16, JIS C3342 Sec.6.6,JIS C3005 Sec.4.16
Polyethylene(Cross-linked polyethylene) insulated and polyvinyl chloride(polyethylene) sheathed fire-resistant cables CNS 11359 Sec.5.6, CNS 689 Sec.16
Fire-resistant wires CNS 10314 Sec.6.6,CNS 689 Sec.16
Heat-resistant wires CNS 679 Sec.5.6,CNS 689 Sec.16
Low smoke free halogen wires & cables IEC60502-1 Sec.18.3,IEC60811-1-1 Sec.9.1
Test methods for aging test
test sample test methods
Cross-linked polyethylene insulated polyvinyl chloride jacketed power cables CNS 2655 Sec.4.3,CNS 689 Sec.17, JIS C3605 Sec.6.7,JIS C3005 Sec.4.17, IEC60502-1 Sec.18.3 & 18.4, IEC60811-1-1 Sec.9.1 & 9.2,IEC60811-1-2 Sec.8.1
Polyvinyl chloride insulated wires CNS 679 Sec.5.7,CNS 689 Sec. 17, JIS C3307 Sec.6.7,JIS C3005 Sec.4.17            
Polyvinyl chloride insulated polyvinyl chloride sheathed cables CNS 3301 Sec.5.7,CNS 689 Sec.17, JIS C3342 Sec.6.7,JIS C3005 Sec.4.17
Polyethylene(Cross-linked polyethylene) insulated and polyvinyl chloride(polyethylene) sheathed fire-resistant cables CNS 11359 Sec.5.7, CNS 689 Sec.17
Fire-resistant wires CNS 10314 Sec.6.7,CNS 689 Sec.17
Heat-resistant wires CNS 679 Sec.5.7,CNS 689 Sec.17
Low smoke free halogen wires & cables IEC60502-1 Sec.18.3,IEC60811-1-1 Sec.9.1, IEC60811-1-2 Sec.8.1
  • Specific Optical Density test
  • Halogen Acid Content test
  • Smoke Density test
  • pH Value/Combustion acid gas test
  • Conductivity test
  • Oxygen Index test
Test methods for specific Optical Density test
test sample test methods
Polymer and composite materials ASTM E662
Electric Wires & cables ASTM E662
Test methods for Halogen Acid Content
test sample test methods
Polymer and composite materials IEC 754-1(1982)
Electric Wires & cables IEC 754-1
Test method for Smoke Density test
test sample test methods
Electric wires & cables IEC 61034-1 ,IEC 61034-2
Test methods for pH Value and Combustion acid gas test
test sample test methods
Non-metal compound of cable pieces IEC 60754-2 Sec.8.1.2.1 & Sec. 8.2
Test methods for Conductivity test
test sample test methods
Test methods for Conductivity test IEC 60754-2 Sec. 8.1.2.2 & Sec. 8.2
Test methods for Oxygen Index test
test sample test methods
Polymer materials and wires & cables ASTM D2863
  • Fire-resistant test
  • Vertical flame spread test
  • Vertical tray flame test
Test methods for Fire-resistant test
test sample test methods
Polyethylene(Cross-linked polyethylene) insulated and polyvinyl chloride(polyethylene) sheathed fire-resistant cables CNS 11359 Sec.5.10.1
Low smoke free halogen wires & cables IEC331、IEC60331-11、IEC60331-21、 IEC60331-23
Test methods for Vertical flame spread test
test sample test methods
Low smoke free halogen wires & cables IEC60332-3
Test methods for Vertical tray flame test
test sample test methods
Low smoke free halogen wires & cables IEEE383