Leaky Coaxial Cable

Asia Pacific Wire & Cable Corp Ltd.
Leaky Coaxial Cables (RADIALCX) can be laid at the places in which radio wave can not cover, such as tunnel or basement, as an auxiliary communication.
Leaky Coaxial Cable
1/2”、7/8”、1-1/4”、1-5/8” as following :
Construction
Item | Specification | ||||||||
---|---|---|---|---|---|---|---|---|---|
RADIALCX 1/2” | RADIALCX 7/8” | RADIALCX 1-1/4” | RADIALCX 1-5/8” | ||||||
Inner conductor | Material | Copper clad aluminum wire | Copper tube | Copper tube | Corrugated copper tube | ||||
Dia(mm) | 4.9 | 9.1 | 13.2 | 17.3 | |||||
Dielectric | Material | Foam polyethylene | |||||||
Dia(mm) | 12.5 | 22.5 | 32.5 | 42.5 | |||||
Outer conductor | Material | Slot copper/Aluminum tape | |||||||
Dia(mm) | 13.0 | 23.0 | 33.0 | 43.0 | |||||
Sheath | Material | Low smoke free halogen compound | |||||||
Dia(mm) | 15.0 | 28.7 | 38.1 | 48.0 | |||||
Cable weight (kg/m) | 0.34 | 0.77 | 1.16 | 1.50 | |||||
Cable identification | |||||||||
PACIFIC | RADIALCX | 7/8” | CFC | ─ | FR | 50 OHM | MMYY | IEC 60332-1 IEC 60332-3 | xxxM |
(A) | (B) | (C) | (D) | (E) | (F) | (G) | (H) | (G) | |
|
Mechanical properties
Item |
Specification | |||
---|---|---|---|---|
RADIALCX 1/2” | RADIALCX 7/8” | RADIALCX 1-1/4” | RADIALCX 1-5/8” | |
Min. Bending radius (mm) | 125 | 250 | 380 | 700 |
Max. Tensile force(kgf) | 110 | 140 | 170 | 170 |
Clamp spacing(M) | 0.5 | 0.9 | 1.3 | 1.5 |
Temperature range | -40℃~+60℃ | -40℃~+60℃ | -40℃~+60℃ | -40℃~+60℃ |
Electrical properties(at 20℃)
Item |
Specification | |||
---|---|---|---|---|
RADIALCX 1/2” | RADIALCX 7/8” | RADIALCX 1-1/4” | RADIALCX 1-5/8” | |
Inner conductor resistance(Ω/km) | 1.6 | 1.0 | 0.8 | 0.8 |
Outer conductor resistance(Ω/km) | 5.0 | 3.0 | 1.5 | 1.5 |
Insulation resistance(MΩ-km) | >1000 | >1500 | >1500 | >1500 |
Capacitance(pF/m) | 75 | 75 | 75 | 75 |
Velocity of propagation (%) | 88 | 88 | 88 | 88 |
Impedance(Ω) @200MHz | 50 | 50 | 50 | 50 |
VSWR | <1.5 | <1.5 | <1.5 | <1.5 |
Attenuation(dB/100m) | Table1 | Table1 | Table1 | Table1 |
Coupling loss(dB) | Table2 | Table2 | Table2 | Table2 |
Table 1 Attenuation (Nominal)
Freq. MHz | (dB/100m) | |||
---|---|---|---|---|
1/2” | 7/8” | 1-1/4” | 1-5/8” | |
75 | 2.17 | 0.75 | 0.70 | 0.60 |
150 | 3.10 | 1.23 | 0.97 | 0.77 |
450 | 5.74 | 2.79 | 2.19 | 1.50 |
800 | 8.78 | 3.38 | 3.01 | 2.10 |
870 | 9.24 | 4.51 | 3.55 | 2.24 |
900 | 9.42 | 4.56 | 3.59 | 2.25 |
960 | 9.74 | 4.74 | 3.37 | 4.24 |
1800 | 21.98 | 8.99 | 7.07 | 4.50 |
1900 | 22.72 | 9.49 | 7.46 | 4.71 |
2000 | 23.45 | 9.65 | 7.59 | 5.25 |
2200 | 25.48 | 11.54 | 9.08 | 7.40 |
2400 | 27.93 | 15.00 | 11.80 | 8.27 |
※ The maximum value shall not exceed 115%of nominal value.
Table 2 Coupling loss
Frequency MHz | Specification | ||||
---|---|---|---|---|---|
RADIALCX 1/2” | RADIALCX 7/8” | RADIALCX 1-1/4” | RADIALCX 1-5/8” | ||
75 | 50% | 54 | 55 | 55 | 64 |
95% | 65 | 66 | 61 | 78 | |
150 | 50% | 61 | 62 | 60 | 74 |
95% | 72 | 65 | 69 | 82 | |
450 | 50% | 68 | 75 | 68 | 80 |
95% | 79 | 84 | 76 | 90 | |
800 | 50% | 69 | 69 | 68 | 79 |
95% | 82 | 82 | 78 | 89 | |
870 | 50% | 73 | 73 | 69 | 81 |
95% | 84 | 84 | 78 | 90 | |
900 | 50% | 70 | 70 | 69 | 77 |
95% | 79 | 79 | 78 | 90 | |
960 | 50% | 72 | 72 | 69 | 80 |
95% | 83 | 83 | 78 | 90 | |
1800 | 50% | 63 | 63 | 69 | 72 |
95% | 74 | 74 | 78 | 84 | |
1900 | 50% | 64 | 64 | 69 | 72 |
95% | 73 | 73 | 78 | 82 | |
2000 | 50% | 66 | 66 | 69 | 71 |
95% | 72 | 72 | 78 | 83 | |
2200 | 50% | 62 | 62 | 69 | 71 |
95% | 71 | 71 | 78 | 83 | |
2400 | 50% | 64 | 64 | 69 | 69 |
95% | 75 | 75 | 78 | 79 |
※The maximum value shall not exceed 10dB of nominal value.