Special Wire

Asia Pacific Wire & Cable Corp Ltd.
According to applications the cable can be applied to internal wiring for solar panel, automobile, motorcycle, rail vehicle and boat.
For cabling of solar modules among themselves and as extension cable between the individual module strings or DC/AC inverter.
90 ℃ 600V | ||||||||
---|---|---|---|---|---|---|---|---|
Conductor | Insulation | Max. Cond. Resist. |
Allow Current |
Diel. Strength |
Stand. Length |
|||
Size | Composition | Diam. | Avg. Thick. |
Apox. O.D. |
||||
AWG | No/mm | mm | mm | mm | (20℃) Ω/km | A | ACKV/1min | FT |
16 | 26/0.254 | 1.5 | 1.7 | 4.9 | 14.6 | 22.7 | 3.0 | 1000 |
14 | 41/0.254 | 1.9 | 1.7 | 5.4 | 8.96 | 30.2 | ||
12 | 65/0.254 | 2.4 | 1.7 | 5.8 | 5.64 | 39.7 | ||
10 | 65/0.32 | 3.0 | 1.7 | 6.4 | 3.55 | 52.5 |
90 ℃ 1000V | ||||||||
---|---|---|---|---|---|---|---|---|
Conductor | Insulation | Max. Cond. Resist. |
Allow Current |
Diel. Strength |
Stand. Length |
|||
Size | Composition | Diam. | Avg. Thick. |
Apox. O.D. |
||||
AWG | No/mm | mm | mm | mm | (20℃) Ω/km | A | ACKV/1min | FT |
16 | 26/0.254 | 1.5 | 2.2 | 5.9 | 14.6 | 24.0 | 3.0 | 1000 |
14 | 41/0.254 | 1.9 | 2.2 | 6.3 | 8.96 | 31.7 | ||
12 | 65/0.254 | 2.4 | 2.2 | 6.8 | 5.64 | 41.5 | ||
10 | 65/0.32 | 3.0 | 2.2 | 7.4 | 3.55 | 54.6 |